Description
Description: PDU 3PHASE 208V 8.6 12.6KW 42 C13 12 C19
Tripp Lite PDU 3-Phase 208V 8.6/12.6kW 42xC13 12xC19 20A Vertical 0URM – Power distribution strip (rack-mountable) – 35 A – AC 200-240 V – 12.6 kW – 3-phase – output connectors: 54 (IEC 60320 C13, IEC 60320 C19) – 0U
The PDU3V20D354A 8.6/12.6kW 3-Phase Vertical Power Distribution Unit (PDU) Outlet Strip is a required accessory option for Tripp Lite’s PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530, PDU350AT6H50 and other 3-phase auto-transfer switch (ATS) PDUs that specify compatibility with this model. It’s ideal for high-density equipment racks in data centers and server rooms.
When used with 208V ATS models with a 35A input rating (such as PDU350AT6H50), the PDU3V20D354A supports up to 12.6kW total output with 20A maximum full balanced load per phase combination output bank (L1-L2, L2-L3, L3-L1). When used with 208V ATS models with a 24A input rating (such as PDU330AT6L2130, PDU330AT6L1530 or PDU330AT6L15), it supports up to 8.6kW total output with 13.9A maximum balanced load per phase combination output bank.
The 42 C13 and 12 C19 single-phase outlets receive power from the connected ATS PDU. The outlets are interlaced to help you balance loads by spreading connections across the phase combinations (L1-L2, L2-L3, L3-L1) throughout the rack. Each outlet is numbered and color-coded to help you keep track of connected devices and which phase combination powers each. The 0.76 m (2.5-foot) power cord with 8-position plug connects directly to the PDU’s rear receptacle.
The PDU3V20D354A’s rugged all-metal housing mounts in compatible racks in seconds with no tools needed. Vertical 0U installation reduces cord clutter and improves airflow through the rack.
Whats in the Box
- PDU3V20D354A 8.6/12.6kW 3-Phase Vertical PDU Outlet Strip
Key Selling Points
Compatible with PDU330AT6L21, PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530, PDU350AT6H50 and other select Tripp Lite 3-phase ATS PDUs
Ideal for high-density equipment racks in data centers and server rooms
Supports up to 12.6kW total output with 20A maximum per output bank when connected to 208V ATS models with a 35A input rating(such as PDU350AT6H50)
Supports up to 8.6kW total output with 13.9A maximum per output bank when connected to 208V ATS models with a 24A input rating(such as PDU330AT6L21, PDU330AT6L2130, PDU330AT6L1530 or PDU330AT6L15)
Heavy-duty 2.5 ft. power cord plugs directly into the ATS PDU with a Unique 8-position plug
Single-phase outlets are interlaced to help you balance loads by spreading connections across the phase combinations(L1-L2, L2-L3, L3-L1) throughout the rack
Numbered and color-coded for easy identification of connected devices and which phase combination output bank powers them
Preinstalled mounting buttons for toolless vertical rack-mounting in compatible racks
Saves rack space, improves airflow and reduces cord clutter by locating outlets closer to connected devices
Preinstalled ground screw for connecting devices that require chassis ground
Heavy-duty all-metal housing provides durability and reliability in demanding high-density rack environments